Neo-Vista

The Neo Vista is a portable vein illumination device for neonates and babies. When activated it displays a map of the vasculature on the surface of the skin, allowing clinicians to verify patency and avoid valves or bifurcations.

It is a more effective venepuncture procedure, with less patient discomfort, resulting in higher patient satisfaction and ensuring shorter procedure time.

Neo-Vista Features

  • Easy to use, economical and hands free
  • Increases the success rate with first attempt of venipuncture
  • Splash proof, so that the user can clean it with disinfectant according to Hospital guidelines
  • Minimum maintenance required

Click here to download leaflet and usage instructions in PDF format (requires adobe acrobat reader)

  • Ordering Info
  • Specifications
  • Attachments
  • Additional Images

Sizes available:

When ordering, please quote the following (minimum quantity 1 box):

Order # Dimensions

Qty/box

TRANS1 108mm x 32mm (max) x 38mm (max) 20

Neo-Vista - Technical Specifications

Lighting Source   Ø5 CAP LED
Working Mode   On-Off
Lumen  7 LM
Runtime  12 hours
Peak Beam Intensity  26 cd
Beam Distance  5m
Impact Resistance  1m
Battery Type  2 x AAA Alkaline
Switch Model  Push Button
Output Power  0.12W
Batteries Removable  Yes
Dimensions (mm)  10.8 x 3.8 x 3.2cm
Net Weight  26.5g
Material  ABS Plastic
Finishing  Abrasive
Lens Dimension (mm)  24 x 15.8 x 6.3mm
Lens Material  PC
Switch Position  body
Logo Position  Body and Battery cover

 

Usage Instructions

Important:  Please read all the instructions, warnings and information below carefully, ensuring that you fully understand them prior to using the Neo-Vista transilluminator.

1.    Insert the batteries into the compartment of the Neo-Vista.

2.    To activate, press the On/Off button.

3.    Hold the Neo-Vista or put on a flat surface and place the palm of the patient’s hand over the LED of the device.

4.    Dimming the room lights will aid in detection using the Neo-Vista.

5.    Insert the IV-Catheter then switch off the Neo-Vista.

N.B. The patient’s fingers can be draped over the Neo-Vista in order to stretch the skin, so assisting with the location of veins.

Information:  

1.    Replace old batteries with new AA type batteries once exhausted, it is recommended that both batteries are replaced at the same time.

2.    To clean the Neo-Vista, please refer to the relevant hospital’s regulations and protocols that apply.

3.    Once the Neo-Vista in no longer operational i.e. LED display faulty and/or On/Off switch broken, ensure disposal is achieved according to the hospital’s guidelines.

General  Specifications:

Battery type: AA Alkaline
Compliance: Standard: IEC 60601-1 General requirements for Medical Equipment
LED type:  Φ5 CAP LED
Output Light wavelength: 620 nm - 635 nm  